Customization: | Available |
---|---|
Usage: | Drone & WiFi Jammer Power Amplifier |
Type: | Wireless |
Suppliers with verified business licenses
Item
|
Parameter
|
Remarks
|
||
Operating Voltage
|
28V
|
24-30V
|
||
Conversion efficiency
|
≥42%
|
@100W typical
|
||
Controllable output power
|
10W~100W
|
Software set power level
|
||
ALC power adjustment range
|
≥30 dB
|
Voltage Controlled Attenuation
|
||
Gain
|
50±1.0 dB
|
|
||
In-band fluctuation
|
≤2.5 dB
|
peak-to-peak
|
||
spurious
emission
|
|
≤-15dBm/1MHz
|
Measured when the center frequency plus CW signal to the maximum output power
|
|
out of work band
|
9KHz~1GHz
|
No higher than normal noise floor clutter
|
||
1G~12.75GHz
|
||||
Maximum allowable input power
|
≥+10 dBm
|
Lasts 1min without damage
|
||
Input VSWR
|
≤1.35 dBm
|
Add +28V, standard network output -10dBm
|
||
Output VSWR
|
≤1.30 dBm
|
No power, standard network output -10dBm
|
||
≤1.35 dBm
|
Power On, Dual Directional Coupler Test
|
|||
High and low temperature test
|
Working ambient temperature (ºC)
|
-10~+65
|
Low temperature can start, monitoring works normally
|
|
Gain Stability
|
±1.5 dBm @-40ºC~+65ºC
|
|
||
power stability
|
±1 dBm @-40ºC~+65ºC
|
|
||
Power Requirements
|
≥8A @+28Vdc;
|
CW output 100W
|
||
Power supply interface, monitoring interface RS485
|
7W2
|
Male
|
||
RF output connector
|
N-F connector
|
|||
LCD liquid crystal display
|
Display frequency, power, switch status
|
|||
with 3 LED lights
|
POWER: Power indication;
RUN: Running indication;
ALARM: Alarm indication;
|
|||
Built-in cooling fan
|
Modules can be run separately
|
|||
Physical dimension
|
155 x 125 x 60mm
|
|||
Weight
|
1.6Kg
|
|||
Appearance (how to use)
|
Black integrated module with fan (single or portable use)
|
Monitoring
|
Function Description
|
Remarks
|
|
Amplifier part setting parameters
|
Amplifier switch
|
Turn the amplifier on or off
|
|
Alarm switch
|
Enable and disable the alarm function
|
|
|
Downlink Power Control
|
The maximum output power of the power amplifier can be set, the adjustment range is ≥20dB, and the high, medium and low power levels can be set
|
|
|
Amplifier over temperature alarm
|
The high temperature power amplifier shutdown threshold can be set, the power amplifier temperature exceeds 85 degrees, it will automatically shut down; 65 degrees will automatically restore
|
|
|
Amplifier overpower alarm
|
The actual power value is 2dB higher than the downlink ALC start control threshold and close
|
|
|
Power amplifier standing wave alarm
|
When the standing wave detection of the power amplifier is greater than 4, the power amplifier is automatically turned off
|
|
|
Amplifier overcurrent alarm
|
When the detection current of the power amplifier exceeds 12A, the power amplifier is automatically turned off
|
|
|
Amplifier under-power alarm
|
When the power amplifier detection power is less than 37dBm, an under-power alarm is displayed
|
|
|
Amplifier overvoltage alarm
|
When the power amplifier voltage exceeds 32V, the power amplifier will automatically shut down
|
|
|
|
Amplifier switch status
|
If the power amplifier is set to "OFF", the query should be the state of the power amplifier off; otherwise, the state of the
power amplifier will be turned on. |
|
Downstream output power level value
|
Detect power amplifier output power value, detection range (Pomax+2, Pomax-20)
|
Detection accuracy:Pout±1dB
|
|
Downward standing wave ratio
|
The standing wave is normally 1.2, when the load is mismatched, the query value is 4.0
|
|
|
Temperature query
|
Detect the internal temperature of the module, detection range: -40ºC~+100ºC
|
detection error:±3ºC
|
|
ALC value query
|
The displayed value is equal to the actual set ALC value
|
|
|
Voltage detection
|
Detection module working voltage
|
|
|
Current Detection
|
Detection module operating current
|
|
|
Signal generator settings
|
Frequency setting mode 1
|
Any single frequency point setting within the range
|
The frequency setting accuracy is 1M, the maximum frequency bandwidth is 500M, and the maximum is 6G
|
Frequency setting mode 2
|
Set the broadband frequency sweep mode, parameters such as frequency, interval, and step can be set
|
|
|
Frequency setting mode 3
|
Set any 4 sub-frequency segments within the bandwidth, and a single sub-segment needs to be incremented
|
|
|
module communication
|
RS485
|
||
Interface definition
|
+:28V,-: GND; control bit 1:485A,2:485B
|